Fire-Rated Wallpaper in Malaysia: B-s1,d0 and ASTM Class A Explained
VÉLLANO STUDIO · 11 MIN READ · ·

Fire-rated wallpaper in Malaysia: what B-s1,d0, ASTM E84 Class A, A2-s1,d0 and Class 0 mean, where each is specified and which materials hold B-s1,d0.
Fire-rated wallpaper in Malaysia is usually specified to one of two classifications: the European EN 13501-1 B-s1,d0 or the American ASTM E84 Class A. Both describe how little a wallcovering adds to a fire's growth and smoke. VÉLLANO's two fire-rated materials, Fabric Backed FR+ and DuraFlex FR, hold both, so one material can answer either kind of specification.
This guide explains what each code means, how the two compare, what to do when an older specification quotes a different standard, where fire-rated wallcovering is usually asked for, and what to hand the consultant at submission. Which class a particular wall needs is decided by the building's fire strategy and its fire engineer, not by the wallcovering supplier.
What "fire-rated wallpaper" actually means
There are two quite different ideas behind the words "fire rating", and specifications sometimes mix them up.
- Reaction to fire describes how a surface material behaves once it is exposed to flame: how fast fire spreads across it, how much heat and smoke it releases, and whether it drops burning debris. This is what wallcovering classifications measure.
- Fire resistance describes how long a whole wall, door or floor assembly holds back a fire (for example, 60 or 120 minutes). That comes from the construction behind the finish, such as the board, blockwork or partition system.
A fire-rated wallcovering is therefore a low-contribution lining. It helps keep corridors and escape routes from feeding a fire or filling with smoke. It does not add fire-resistance minutes to the wall it is hung on. When a drawing note asks for a "fire-rated wall", check whether it means the partition or the finish.

EN 13501-1: what "B-s1,d0" means
The European reaction-to-fire classification has three parts, and each answers a separate question.
- The letter (A1, A2, B, C, D, E, F) rates the material's contribution to fire growth. A1 and A2 are essentially non-combustible materials such as stone or mineral board. B means a very limited contribution, and it is the best class most decorative organic finishes can realistically reach.
- The s figure rates smoke production, from s1 (lowest) to s3.
- The d figure rates flaming droplets or particles, from d0 (none) to d2.
B-s1,d0 therefore reads as: very limited contribution to fire, the lowest smoke class and no flaming droplets. For a printed vinyl wallcovering, it is the strongest result you will normally see on a specification.
ASTM E84: what "Class A" means
ASTM E84 is the American surface-burning test, often called the tunnel test. A sample lines the roof of a long tunnel, a flame is applied at one end, and two numbers are recorded:
- Flame Spread Index (FSI): how far and how fast the flame travels along the sample.
- Smoke Developed Index (SDI): how much smoke the burning sample produces.
The results are grouped into classes. Class A (sometimes written Class I) needs an FSI of 0 to 25 and an SDI of 450 or less. Class B allows an FSI of 26 to 75 and Class C 76 to 200, both with the same smoke limit. Specifications from American and international hotel brands usually ask for Class A on corridors and public areas.
B-s1,d0 vs ASTM Class A compared
The two classifications come from different tests, so a result in one cannot be converted into the other. A material that holds both covers the widest range of specifications.
| EN 13501-1 B-s1,d0 | ASTM E84 Class A | |
|---|---|---|
| Origin | European classification | American test standard |
| What it measures | Contribution to fire growth, smoke and flaming droplets | Flame spread and smoke along a tunnel sample |
| How the result is written | Letter + smoke class + droplet class | Class A, B or C from the FSI and SDI |
| Best result for a decorative wallcovering | B-s1,d0 | Class A (FSI 0–25, SDI ≤ 450) |
| Where you see it asked for | European-style specifications, consultants working to EN standards | International hotel brand standards, American-style specifications |
| VÉLLANO materials that hold it | Fabric Backed FR+, DuraFlex FR | Fabric Backed FR+, DuraFlex FR |
For the other abbreviations on a fire or spec sheet, see the wallcovering specification glossary.
A2-s1,d0, A2fl-s1 and Class 0: codes often confused with B-s1,d0
Three other codes turn up in searches and older specifications. None of them is the same as B-s1,d0.
- A2-s1,d0 is the EN 13501-1 class for products of limited combustibility, one step above B. It is normally reached by mineral-based products such as plasterboard or fibre-cement, not by printed vinyl wallcoverings, and VÉLLANO does not claim it. If a specification asks for A2-s1,d0 on a wall finish, ask the consultant whether it applies to the wall build-up or to the surface finish, and whether B-s1,d0 evidence is acceptable for the finish.
- A2fl-s1 is a floor-covering class. The "fl" marks the EN 13501-1 system for floorings, which is tested differently from wall linings, so it does not apply to wallpaper.
- Class 0 is a British term from building guidance and BS 476 testing. It is not a code VÉLLANO publishes for its materials, and it cannot be read across from B-s1,d0 on paper. The next section covers what to do when a specification quotes it.
If your specification quotes a different standard
Older Malaysian and regional specifications sometimes describe wall linings with British BS 476 terms (Part 6 and Part 7, giving "Class 0" or "Class 1"). These are separate test methods. A BS 476 result, a Euroclass and an ASTM E84 class are not automatic equivalents of one another, and nobody can honestly convert one into another on paper.
The classifications VÉLLANO publishes for its fire-rated materials are EN 13501-1 and ASTM E84. If a specification names a different standard, raise it with the consultant or fire engineer early, before samples and strike-offs, and ask whether B-s1,d0 or Class A evidence is acceptable for that project. Send us the specification clause and we will tell you exactly which documents we can provide against it.
Where fire-rated wallcovering is usually specified
The table below shows where consultants most often ask for a fire-rated finish on Malaysian commercial projects. It is a planning guide, not a legal requirement: the fire strategy for the building sets the class for each area, so confirm it with the fire engineer before you specify.
| Area | Fire-rated finish usually asked for? | Typical VÉLLANO choice |
|---|---|---|
| Corridors, escape routes and lift lobbies | Yes, almost always | Fabric Backed FR+ or DuraFlex FR |
| Hotel lobbies, function rooms and public lounges | Usually | Fabric Backed FR+; DuraFlex FR where walls take knocks |
| Hospital corridors, wards and waiting areas | Usually | Fabric Backed FR+ or DuraFlex FR |
| Classrooms, school corridors and assembly halls | Usually | Fabric Backed FR+ or DuraFlex FR |
| Restaurants, cafés and food courts | Often | DuraFlex FR (scrubbable, impact-tolerant) |
| Hotel guest rooms and private offices | Depends on the building | Fire-rated where required; otherwise Luxe non-woven or Eco |
| Homes and show units | Rarely | Eco, Canvas HD+ or Luxe non-woven |
Sector guides go further: the hotel wallcovering specification guide has a zone-by-zone plan, and there are pages for healthcare, education and restaurants and retail.

VÉLLANO's fire-rated materials
Two materials carry both B-s1,d0 and ASTM E84 Class A. Both are 15 oz fabric-backed commercial vinyls with a 51 in (1,295 mm) print width, printed with odourless, GREENGUARD Gold certified Canon UVgel ink. Every design in the library, and your own artwork through bespoke printing, can be printed on either.
| Fabric Backed FR+ | DuraFlex FR | |
|---|---|---|
| Base | 15 oz Osnaburg-backed vinyl | 15 oz/ly commercial vinyl |
| Surface | Commercial fabric-backed finish | Linen-weave emboss |
| Fire classification | B-s1,d0 · ASTM E84 Class A | B-s1,d0 · ASTM E84 Class A |
| Print width | 51 in (1,295 mm) | 51 in (1,295 mm) |
| Emissions | M1, AgBB, GREENGUARD Gold, French A+, SGBC Green Label | M1, AgBB, GREENGUARD Gold |
| Best for | Hotels, hospitals, corridors, offices, education | Hotels, healthcare, high-traffic corridors, F&B |
Choose Fabric Backed FR+ when the artwork is detailed or photographic and you want the cleanest surface. Choose DuraFlex FR when the wall will be cleaned often or knocked by trolleys and luggage; its linen-weave emboss also softens the print slightly. The textures and finishes guide shows how each surface changes a design, and you can put both side by side with the material comparison tool.


What about the paper-backed and non-woven ranges?
The Eco paper-backed range, Canvas HD+ and the Luxe non-wovens carry strong indoor-air and durability credentials, but they are not fire-rated. Use them where the fire engineer confirms a rating is not required, such as homes, many hotel guest rooms and some private offices.
One label causes confusion: Luxe Artistry NW is certified to ASTM F793 Type II. That is a durability class for commercial wallcoverings in areas with average to high traffic. It is not a fire classification, so it does not replace B-s1,d0 or Class A on a rated wall. If you want a seamless 3.15 m mural on a wall that must be fire-rated, plan the artwork as 51 in panels on a fire-rated base instead; the mural vs wallpaper guide explains how joins are placed.

Fire submission checklist
Most fire queries on a wallcovering package come from a missing document or a vague clause, not from the material. Before you issue the package, check:
| Item | What to include |
|---|---|
| Classification evidence | The EU fire classification certificate from Downloads; ask us for the full Project Specification Kit |
| Material spec sheet | The spec sheet for the exact material named in the schedule (download it from the material page) |
| Clause | Material name, fire classification, print width and design code, written with the spec clause generator |
| Area schedule | Which walls are fire-rated and which are not, matching the fire strategy drawings |
| Other standards | Any BS 476 or other requirement raised with the consultant before sign-off |
| Samples | An A4 sample or strike-off on the fire-rated material itself (see the samples guide) |
| Installation | An experienced commercial installer for fabric-backed materials; ask us for a referral |
Write what is true: "classified B-s1,d0 to EN 13501-1 and Class A to ASTM E84". Don't write that a wallcovering is "approved" by an authority unless the approval is actually held, because the consultant will ask for it. For the full order of a specification, read how to write a wallcovering specification clause, or send us the project's fire strategy and we will recommend a material.

Fabric Backed FR+
51 IN PRINT WIDTH · B-s1,d0 · CLASS ACommercial fabric-backed- Fire-rated commercial backing
- Fabric-backed, 15 oz
- Ultra-low VOC
- Ultra-low formaldehyde

DuraFlex FR
51 IN PRINT WIDTH · B-s1,d0 · CLASS ALinen-weave emboss- Fire-rated commercial backing
- Fabric-backed, 15 oz
- Ultra-low VOC
- Ultra-low formaldehyde

Luxe Artistry NW
124 IN PRINT WIDTHArtist canvas weave
Eco Tex
39 IN PRINT WIDTHFine textured
Canvas HD+
57 IN PRINT WIDTHWoven canvasFrequently asked questions
Is wallpaper fire resistant?
Ordinary decorative wallpaper is not fire-rated. A fire-rated wallcovering is tested for reaction to fire, meaning how little it adds to flame spread and smoke. VÉLLANO's Fabric Backed FR+ and DuraFlex FR are classified B-s1,d0 to EN 13501-1 and Class A to ASTM E84. Neither makes the wall itself fire-resistant; that comes from the construction behind it.
Is B-s1,d0 the same as ASTM Class A?
No. They come from different tests. B-s1,d0 is the European EN 13501-1 class for fire growth, smoke and flaming droplets. ASTM E84 Class A is the American tunnel test, needing a flame spread index of 0 to 25 and a smoke index of 450 or less. A material holding both covers most specifications.
Which areas need fire-rated wallcovering?
Corridors, escape routes, lift lobbies and public areas of hotels, hospitals, schools and restaurants are where a fire-rated finish is most often asked for. The class each wall needs is set by the building's fire strategy, so confirm it with the fire engineer rather than assume.
My specification asks for BS 476 Class 0 or Class 1. Can I use B-s1,d0?
BS 476 Part 6 and Part 7 are separate British tests, and their results are not automatic equivalents of a Euroclass or ASTM class. VÉLLANO publishes EN 13501-1 and ASTM E84 classifications. Ask the consultant early whether that evidence is accepted, and send us the clause so we can confirm which documents we can supply.
What is the difference between A2-s1,d0 and B-s1,d0?
Both are EN 13501-1 classes. A2 is for products of limited combustibility, usually mineral-based boards, and sits a step above B. B-s1,d0 is the best class a printed vinyl wallcovering can normally hold, and it is what VÉLLANO's Fabric Backed FR+ and DuraFlex FR are classified to. If a specification asks for A2-s1,d0, check whether it means the wall build-up or the finish.
What does A2fl-s1 mean?
A2fl-s1 is a floor-covering class under EN 13501-1. The fl marks flooring, so it does not apply to wallpaper or wall linings, which use the same letters without fl (for example B-s1,d0).
What is a Class 0 fire rating?
Class 0 is a British term from building guidance, tied to BS 476 Part 6 and Part 7 test results. It is not the same as B-s1,d0 or ASTM Class A, and one cannot be converted into the other on paper. If a specification asks for Class 0, send us the clause and ask the consultant what evidence they will accept.
Is ASTM F793 Type II a fire rating?
No. ASTM F793 Type II is a durability class for commercial wallcoverings in average to high-traffic areas. Luxe Artistry NW holds it, but it is not fire-rated. For a wall that must be fire-rated, specify Fabric Backed FR+ or DuraFlex FR, both classified B-s1,d0 and ASTM E84 Class A.
Can any design be printed on a fire-rated material?
Yes. Every VÉLLANO design, and your own artwork, can be printed on Fabric Backed FR+ or DuraFlex FR. Both print 51 in (1,295 mm) wide, so a large mural is split into panels; the joins are planned around faces, logos and other key details before printing.
What documents do I need for a fire submission?
Usually the classification certificate, the spec sheet for the named material and a clear clause stating the class. The EU fire classification certificate is in Downloads, and we can send the full Project Specification Kit. Check with the consultant whether any other test evidence is required.
Next article



